AquaEnergy Expo is a global exhibition in the water and energy field which includes a magazine, a Knowledge hub, and a virtual expo.

Menu
Digital Anti-corrosion Double Electric Grade Electromagnetic Flow Meter
(0 reviews)
Get Price
(614) Views
(0) Contacts


Contact Company

HEBEI SHANGHONG METERS TECHNOLOGY CO.,LTD
Hebei, China
(4066) Views
(5) Contacts

Technical Performance Parameters 
Main Power  
AC220V 50Hz /DC24V/3.6V 
Power consumption  
<15W (Supporting power consumption with sensors) 
Display and buttons 
Display in Chinese and English can display instantaneous flow, cumulative flow, and alarm display (excitation open circuit alarm, empty pipe alarm, flow limit alarm). 4 membrane touch switches for data sets 
Counter 
Forward total, reverse total 
Output Signal 
Analog output 
Two-way, fully isolated 0~10mA/4~20mA 
Load resistance: 0 ~ 1.5kΩ when 0 ~ 10mA; 0 ~ 750Ω when 4 ~ 20mA 
Frequency output 
Forward and reverse flow output, the upper limit of output frequency can be set within 1 ~ 5000Hz. Open collector bidirectional output of transistor with photoelectric isolation. The external power supply is not greater than 35V, and the maximum current of the collector when conducting is 50mA. 
Alarm Output 
Two open-collector alarm outputs with photoelectric isolation transistors. The external power supply is not greater than 35V, and the maximum current of the collector when it is turned on is 250mA. Alarm status: fluid empty pipe, excitation disconnection, flow overrun. 
Pulse output 
Forward and reverse flow output, the upper limit of the output pulse can reach 5000CP / S. The pulse equivalent is 0.0001 ~ 1.0m³ / P. The pulse width is automatically set to 20ms or a square wave. Open collector output of transistor with photoelectric isolation. The external power supply is not greater than 35V, and the maximum current of the collector when conducting is 50mA 
Matching accuracy 
± 0.5% of market value, optional ± 0.2% or 1% of indicated value 
Damping time constant 
Continuous variable from 0 ~ 100s (90%) time grading optional 
communication 
Optional RS232C or RS485 serial communication interface, HART communication protocol, with anti-lightning protection 
Loss of power 
The internal design of the instrument has a power-off clock, which can store 16 drop-out records (10 years) 
Protection level 
IP65 
Explosion-proof mark  
Exs[ia]ia||cT5 
Electromagnetic Flowmeter Electrode Material 
Material 
Material Corrosion Performance 
316L electrode 
Application: domestic/industrial water, sewage PH value: within 6/7/8 Not applicable: corrosive media such as hydrofluoric acid / hydrochloric acid/chlorine/iodine 
HB 
Application: certain concentrations of hydrofluoric acid and other oxidizing acids and non-oxidizing hydrochloric acid, alkali solution with a concentration of not less than 70% sodium hydroxide. PH value: within 5/6/7/8 Not applicable: Oxidizing acids such as nitric acid 
HC 
Application: corrosion resistance to oxidizing salts or environments containing other oxidants, especially to seawater. PH value is within 6/7/8/9 Not applicable: hydrochloric acid, dilute sulfuric acid, phosphoric acid, and other reducing acids and chlorides 
Ti 
Application: chloride, hypochlorite, seawater, oxidizing acid. PH value: within the range of 6/7/8/9/10 Not applicable: hydrochloric acid, sulfuric acid, and other acidic media 
Ta 
Application: concentrated hydrochloric acid, nitric acid, sulfuric acid, and other acid liquids, including boiling hydrochloric acid and nitric acid. PH value: within 3/4/5/6 Not applicable: alkali, hydrofluoric acid, fuming sulfuric acid 
Pt 
Various acids, bases, and salts. Not included: Royal Water 
 
 
 
 
 

 Electromagnetic Flow Meter Features: 

1. Clear LCD display screen, display instantaneous flow and cumulative flow respectively 
2. Advanced excitation technology, brief excitation circuit with stability and reliability 
3. Pioneering fuzzy algorithm technology applies to the measurement of electromagnetic flowmeter with the performance of artificial intelligence 4. Empty and full pipe measurement technique to avoid false alarms 
5. With low conductivity measurement function 
6. Prompt response design for high resistance, undistorted collection of weak signals and prompt reaction for flow change , the range rate can achieve 100:1 7.Various optional output communication interfaces

Product Reviews
You must Login/Register to can submit your review

All Rights Reserved to AquaEnergy Expo © 2026