  • Lateral Flame Spread Testing Equipment is used to evaluate combustion characteristics of rail materials and ship materials and measures the spread rate of flame, the flame for ignition by distances, CFE (Critical Flux at Extinguishment), and total heat release. 
  • This test method originated from ISO 5658-2 (Reaction to fire tests Spread of flame- Part 2 Lateral spread on building products in vertical configuration) and measures combustion characteristics of the vertical specimen (155mmX800mm).
  • ​ISO 5658-2: Reaction to fire tests Spread of flame - Part 2 Lateral spread on building products in a vertical configuration
  • IMO Resolution A. 653(16): Recommendation on fire test procedures for flammability of bulkhead, ceiling, and deck finish materials
  • ​ASTM E 1317: Standard test method for flammability of marine surface finishes

    Place of Origin CHINA
    Model Number SFT
    Brand Name AI
    Certification ISO
    Electrical 110V AC 60Hz / 230V AC 50Hz, 10A
    Ambient Temperature 10°C to 35°C
    Gas supplies Propane Gas, Methane Gas, Compressed Air
    Optional gas Acetylene Gas
    Dimensions 1650 mm (W) x 810 mm (H) x 1985 mm
    Weight 228KG
    Applicable standards ISO 5658-2 IMO Spread of Flame Apparatus
    Test Standard ISO 5658-2 ,FTPC Part 5,IMO Res.A.653(16)
    Warranty 1 Year
    Size 1650 Mm (W) X 810 Mm (H) X 1985 Mm
    Power Supply 110V AC 60Hz / 230V AC 50Hz, 10A
    Color White
    Keyword Flame Spread Testing Equipment

    • The Lateral Flame Spread Testing Equipment consists of a radiant panel having dimensions of 280 x 483 mm, mounted vertically, and making an angle of 15° with the specimen.
    • ​The orientation of the panel results in an incident radiant flux that decreases from 50 kW/m² at one end to approximately 1 kW/m² at the other end of the specimen.
    • ​The sample is ignited by a non-impinging, gas/air pilot flame.
    • ​Viewing rakes were placed at a 50-mm spacing along the specimen.
    • ​Heat Flux Meter - for setting the irradiance level at the surface of the specimens, the range from 0-50KW/m2.
    • ​Portable water cooling system without the need for waterworks and plumbing when using the Heat Flux meter.
    • ​The radiant burner system is fully automatic, with spark ignition and safety interlocks.
    • ​MFC (Mass Flow Controller) to easily measure the heat amount of methane gas in measuring critical heat flux.
    • ​Camcorder to observe and save test conditions in a program during tests.
    • To meet the IMO specification a stack is fitted complete with thermopile for estimating heat release rate.
    • ​Records the spread rate of flame after this records ignition and extinguishment time of flame for each distance of specimens. And the other test results are Heat for ignition (MJ/㎡), Heat for sustained burning (MJ/㎡), Critical flux at extinguishment (kW/㎡), Average heat for sustained burning (MJ/㎡), Total heat release (kW), Peak heat release rate (kW).