AquaEnergy Expo is a global exhibition in the water and energy field which includes a magazine, a Knowledge hub, and a virtual expo.

Menu
BS 476-15,ISO5660,ASTM E1354 Cone Calorimeter with Imported Gas Analyzer
(0 reviews)
Get Price
(157) Views
(0) Contacts


Contact Company

Advanced Instruments Co.,Limited
Jiangsu, China
(516) Views
(0) Contacts

  • A calorimeter measures heat release rate(H.R.R), smoke release, ignition time, oxygen consumption, carbon monoxide, carbon dioxide generation, and mass loss rate when the specimen is exposed to the resource of a conical heater.
  • The name of the Cone Calorimeter is derived from the conical heater used by Dr. Vytenis Babrauskas to inspect test specimen (100mm x 100mm) with flux up to 100kW/m2 for the bench scale oxygen depletion of his development.
  •  Cone Calorimeter test is based on the theory that pure combustion calories are in proportion to a necessary amount of oxygen for combustion and 13.1 MJ/kg is generated whenever oxygen 1kg is consumed, and heat emission, ignition time, oxygen consumption, CO, and CO2 generation, and flow of ignited gases as generated from test materials are measured.
Standards
  • ASTM:ASTM D6113,ASTM E1354,ASTM E1740,ASTM F1550
  • BS:BS 476-15
  • ISO: ISO 5660
  • EN:EN 45545-2: 2013
  • GB:GB/T 16172:2007

Place of Origin CHINA
Brand Name AI
Certification ISO
Model Number CCT
Test Standard BS 476-15,ISO5660,ASTM E1354 Etc
Weight 350kg
Power Supply 230 Volts Nominal 50 Amps
Ambient Temperature Operating 10°C To 35°C
Gas Methane, Nitrogen, Compressed Air
Dimensions 1800mm (W) X 900mm X (H) X 2600mm (D)
Size 1300 mm (L) x 1100 mm (D) x 2100 mm (H)

  • Cone Calorimeter with movable analysis cabinet, can be connected with a large heat release rate test system such as ISO 9705, EN 13823, etc, complied with ISO 5660, ASTM E1354, BS 476 Part 15, etc. testing standards.
  • Integrated test body and 19 inches analysis cabinet, embedded PC 15 Inch Touch screen computer, for the whole control and automatic testing.
  • Conical heater rated power 5000W, the heat output of 0 ~ 100kW/m2, using PID temperature controller, while the radiation cone can be horizontal or vertical.
  • Exposed to the central part of the surface of the sample 50 x 50mm range, radiation at the center of the deviation is not more than 2%.
  • The sample weighing range 0 ~ 3000g; accuracy: 0.1g.
  • Auto Split Shutter automatically opened to transmit radiation to the sample.
  • ABB EL3020 Paramagnetic oxygen analyzer, using the method of paramagnetic change to measure the concentration of oxygen in the gas. 
  • The concentration range of 0-25%.
  • Smoke density analysis using a laser system, system consists of a 0.5mW He Ne laser, the main detector, and an auxiliary detector.
  • The exhaust system consists of the fan, the smoke collection cover, the exhaust pipe and orifice plate flow meter, and so on.
  •  Exhaust fan flow rate of 0 ~ 50g/s, precision 0.1g/s.
  • A ring sampler has been installed from the smoke collecting hood at 685 mm, with 12 holes.
  • The exhaust flow rate should be determined by measuring the pressure difference on both sides of the sharp edge orifice 350 mm above the fan, the inner diameter of the sharp edge orifice plate is 57mm + 1mm.
  • ABB SCC-S Gas sampling system comprises a sampling pump, filter, cold trap, wastewater discharge, water filters, and CO2 filters;
  • Portable water cooling system without the need for waterworks and plumbing when using the Heat Flux meter (for ISO 5660).
  • In order to calibrate the response of the whole test system, the use of a square opening brass calibration burner was used to measure the value of the C- coefficient.
  • The data acquisition system is able to record the oxygen analyzer, orifice meter, thermocouple, and other instruments of the output.